ISO 21702 testing quantifies antiviral activity by measuring the reduction of infectious virus particles on treated non-porous surfaces under controlled laboratory conditions.
ISO 21702 Testing: Antiviral Activity on Plastics and Non-Porous Surfaces
What is ISO 21702?
ISO 21702 is a standardized test method used to measure the antiviral activity of treated plastics and other non-porous surfaces.
The method evaluates the reduction of infectious virus particles on a treated surface compared to an untreated control after a defined contact period.
Overview
ISO 21702 is the antiviral counterpart to ISO 22196 and is designed for non-porous materials such as plastics, coatings, metals, and synthetic surfaces.
The method quantifies antiviral performance by measuring the infectivity of viruses before and after exposure to a treated surface using cell-based assays.
At Situ Biosciences, ISO 21702 testing is used to support antiviral claims, validate product performance, and generate defensible data for regulatory and commercial applications.
What ISO 21702 Measures
ISO 21702 measures antiviral activity (R value) based on the reduction in viral infectivity between treated and untreated samples.
The test evaluates antiviral performance by:
- Applying a standardized viral inoculum to the surface
- Covering the inoculum to ensure consistent contact
- Incubating under controlled conditions
- Recovering virus from the surface
- Measuring infectivity using plaque assays
Results are expressed as a log reduction in viral infectivity.
How ISO 21702 Testing Works
ISO 21702 follows a controlled virology-based procedure similar in structure to ISO 22196.
1. Sample Preparation
Test specimens are typically 50 mm × 50 mm flat surfaces with treated and untreated controls.
2. Preparation of Viral Inoculum
Viruses are propagated in host cells and standardized to a known infectivity level (PFU/mL).
3. Inoculation of Test Surfaces
A defined volume (typically 0.4 mL) is applied and covered with a film to ensure uniform distribution.
4. Contact Period
Samples are incubated at:
- 25 ± 1°C
- ≥90% relative humidity
- 24 hours
5. Recovery of Virus
Virus is recovered using a neutralizing solution such as SCDLP broth.
6. Measurement of Infectivity
Recovered virus is quantified using plaque assays on host cell cultures.
7. Calculation of Antiviral Activity
Antiviral activity (R) is calculated based on log differences between treated and untreated samples.
Common Test Viruses
ISO 21702 provides example viruses commonly used in testing:
| Virus | Relevance |
|---|---|
| Influenza A (H3N2) | Enveloped virus, respiratory relevance |
| Feline calicivirus | Non-enveloped virus surrogate |
Additional viruses may be used depending on the intended application, provided they are validated and documented.
Key Test Parameters
| Parameter | Typical Conditions |
|---|---|
| Test Type | Quantitative antiviral |
| Measurement | Log reduction (R value) |
| Temperature | 25 ± 1°C |
| Humidity | ≥90% RH |
| Duration | 24 hours |
| Surface Type | Non-porous materials |
| Endpoint | Viral infectivity (PFU) |
| Standard Organization | ISO |
Benefits of ISO 21702
Quantitative antiviral performance data
Provides measurable reduction in viral infectivity.
Globally recognized standard
Widely accepted for antiviral surface testing.
Applicable across industries
Used for plastics, coatings, medical devices, and consumer products.
Controlled and reproducible conditions
Ensures consistent and comparable results.
Supports regulatory and marketing claims
Generates defensible data for antiviral product claims.
Limitations of ISO 21702
Controlled laboratory conditions
May not fully represent real-world environmental exposure.
Non-porous surfaces only
Not suitable for textiles or porous materials.
Virus-specific results
Performance against one virus may not apply to others.
Requires specialized virology capabilities
Includes cell culture, viral propagation, and plaque assays.
Why Choose ISO 21702 Over Other Methods
ISO 21702 is the preferred method for quantitative antiviral evaluation of hard, non-porous surfaces under controlled conditions.
Improving Test Reliability with Certified Reference Materials
Virology-based testing introduces variability due to biological systems and host cell interactions.
Certified Reference Materials (CRMs) can improve reliability by:
- Verifying test system performance
- Supporting method validation
- Ensuring consistency across studies
- Strengthening ISO 17025 compliance
Situ Biosciences provides CRMs produced in accordance with ISO 17034 and verified using ISO 17025 testing methods.
Learn more here:
https://www.situbiosciences.com/product/certified-reference-materials-for-antimicrobial-testing/
Applications of ISO 21702 Testing
ISO 21702 is widely used in industries where antiviral performance is critical:
- Plastics and polymer materials
- Coatings and treated surfaces
- Medical and healthcare products
- Consumer electronics and appliances
- Public contact surfaces
- Industrial materials
Frequently Asked Questions
What does ISO 21702 measure?
It measures the reduction of infectious virus particles on treated surfaces.
How long does ISO 21702 testing take?
The standard contact time is 24 hours.
What is an R value?
The R value represents the log reduction in viral infectivity between treated and untreated samples.
Can ISO 21702 be used for textiles?
No. It is designed for non-porous surfaces only.
Is ISO 21702 quantitative?
Yes. It provides quantitative results based on viral infectivity (PFU).
ISO 21702 Testing at Situ Biosciences
Situ Biosciences provides ISO 21702 testing for plastics and non-porous materials across a wide range of industries.
Testing programs can be designed to support:
- antiviral performance validation
- product development
- regulatory submissions
- marketing and claims support
For more information about ISO 21702 testing or Certified Reference Materials, please contact Situ Biosciences.
References
ISO 21702 — Measurement of antiviral activity on plastics and other non-porous surfaces
Product Tests
Biodegradation Testing
Analytical Testing
Formulation Analytical Analysis
Product Development
Environmental & Durability Testing
Biodegradability Testing – Chemical Impact
Minimun Inhibitory Concentration
Minimum Biocidal Concentration
Quality Control Testing
Environmental Fate & Toxicology