Antifungal & Mold Resistance Testing

Antifungal and mold resistance testing shows whether a material, coating or finished product resists fungal growth when it is exposed to mold spores in warm, humid conditions. Situ Biosciences runs 14 standard fungal resistance methods, plus custom protocols, in our ISO 17025 accredited lab near Chicago. The methods include ASTM G21, ASTM D3273, AATCC 30, ISO 846 and MIL-STD-810.

Mold growth stains surfaces, weakens materials, causes odors and can trigger product failures or recalls. Testing tells you whether your antifungal additive or treatment works before your product reaches customers.

Which Mold Resistance Test Do You Need?

The right method depends on what your product is made of and where it will be used.

Material or product Method What it measures Typical duration
Plastics and synthetic polymers ASTM G21 Resistance of polymers to fungal growth, rated 0–4 28 days
Plastics exposed to the environment ISO 846 Effect of fungi and bacteria on plastics (Methods A–D) Per method
Interior paints and coatings ASTM D3273 Mold growth on coated panels in an environmental chamber, rated 0–10 4 weeks
Paint films and coatings ASTM D5590 Fungal defacement on an accelerated agar plate assay 4 weeks
Textiles and fabrics AATCC 30 Mildew and rot resistance of textiles 2 weeks (up to 6)
Textiles, quick screen AATCC 30 Part 3 Fungal growth on fabric, 7-day or 14-day version 7 or 14 days
Paper and paperboard ASTM D2020 Mildew resistance of paper 14 days
Adhesives ASTM D4300 Fungal growth and zone of inhibition on adhesive films 4 weeks
Insulation and facings ASTM C1338 Fungal resistance of insulation materials 28 days
Retroreflective sheeting ASTM D4956 Fungus resistance after leaching, with Aspergillus niger 14 days
Military equipment MIL-STD-810 Method 508 Fungal growth on equipment and materials 28 days minimum
Electronic test equipment MIL-PRF-28800F Fungal growth on electronic equipment 28 days
Avionics RTCA DO-160G Fungal resistance of airborne equipment 28 days minimum
Electronics (India) JSS 55555 “Penta-Five” fungal growth test for electronics Per standard
Printed boards IPC-TM-650 2.6.1 Fungus resistance of printed board materials Per standard

Not sure which method fits? Tell us your material, end use and the claim or specification you need to meet, and we will recommend one.

How Mold Resistance Testing Works

  1. Prepare specimens. We test your treated material alongside an untreated control, or a certified reference control.
  2. Inoculate. Specimens are sprayed or inoculated with a spore suspension of the fungi the method specifies, such as Aspergillus brasiliensis, Penicillium, Chaetomium globosum, Trichoderma or Aureobasidium pullulans.
  3. Incubate. Specimens go into a warm, humid chamber that favors mold growth, for 1 to 4 weeks or longer depending on the method.
  4. Rate growth. Our microbiologists rate visible fungal growth at set intervals using the method’s scale.
  5. Report. You receive ratings for each specimen and the control, compared against the method’s criteria or your specification.

How Results Are Rated

Method Rating scale Best result
ASTM G21 0 (no growth) to 4 (heavy growth, more than 60% coverage) 0
ASTM D3273 0 (complete defacement) to 10 (no growth) 10
AATCC 30 Visible growth and, for some tests, loss of fabric strength No growth, minimal strength loss

Fungal Resistance vs. Fungicidal Efficacy

Fungal resistance testing measures whether a surface stops mold from growing on it over weeks. Fungicidal efficacy testing measures whether a disinfectant or sanitizer kills fungi on contact in minutes. If you make a disinfectant with fungicidal claims, you need an efficacy method such as EN 1650 or EN 13697, not a resistance test.

Certified Reference Materials for Antifungal Tests

Situ Biosciences is an ISO 17034 accredited reference material producer. Our certified treated and untreated controls for ASTM G21 and AATCC 30 Part 3 give labs and manufacturers a known result to verify method performance. About our accreditations →

Industries We Test For

Paint & Coatings · Plastics · Textiles · Electronics · Military · Paper · Foam · Concrete

Learn More About Mold and Antifungal Testing

Ready to test? Call 847-483-9950, email info@situtest.com or request a quote →

Frequently Asked Questions

Mold resistance testing exposes a material or product to fungal spores in warm, humid conditions and measures how much mold grows on it over time. Results are compared with an untreated control to show whether an antifungal treatment protects the product.

ASTM G21 tests synthetic polymers such as plastics, rubber and sealants on nutrient-salts agar with no carbon source for 28 days and rates growth from 0 to 4. ASTM D3273 tests interior paints and coatings on panels in a humid environmental chamber for 4 weeks and rates growth from 10 (none) down to 0.

Most methods run 2 to 4 weeks once specimens are inoculated. ASTM G21, ASTM C1338 and MIL-STD-810 run 28 days, and ASTM D2020 runs 14 days. AATCC 30 Part 3 has a 7-day screening version.

Each method specifies its own organisms. Common test fungi include Aspergillus brasiliensis (formerly A. niger), Penicillium species, Chaetomium globosum, Trichoderma species and Aureobasidium pullulans.

A passing result supports claims that a treatment protects the product itself. In the U.S., claims that a product protects people or kills germs on other surfaces may require EPA registration. Ask us about antimicrobial compliance before you finalize label language.

Yes. We can adjust organisms, duration, conditioning (such as leaching or weathering) or specimen size to match your product’s real-world use. We’ll document the changes so your results stay defensible.