Biodegradability Testing for Synthetic Polymers: Navigating EU Microplastics Legislation
Pathways to EU Microplastics Exemption
The European Union’s recently adopted Commission Regulation (EU) 2023/2055 places strict restrictions on the use of intentionally added synthetic polymer microparticles (SPM) across a wide range of products — from cosmetics and detergents to coatings, agricultural formulations, and industrial additives. The goal is clear: prevent microplastics from entering the environment, where they resist degradation and can accumulate in ecosystems and food chains.
However, the regulation also recognizes that not all synthetic polymers behave the same way in the environment. Some can degrade under natural conditions, some dissolve completely, and others are not even carbon-based. For these cases, the EU provides exemptions from the restrictions. Among the available exemptions, proof of biodegradability is the most widely used and scientifically defensible pathway. If a polymer can be shown to degrade according to internationally recognized test methods, it is excluded from the scope of the restriction.
This makes OECD and ISO biodegradability testing central to compliance. The regulation specifies which tests may be used, how results are evaluated, and what conditions apply.
How the EU Organizes Test Methods
The legislation divides permitted biodegradability tests into five groups, each with its own logic and criteria.
Meeting the pass criteria in any Group 1–3 method is enough to prove the polymer is degradable and therefore exempt from restriction.
If using Group 4 or 5 simulation tests (outside agriculture/horticulture), the polymer must pass across three environmental compartments:
-
Compartment 1: fresh, estuarine, or marine water
-
Compartment 2: sediment or water/sediment interface
-
Compartment 3: soil
Group 1 – Ready Biodegradability
Methods:
Pass Criteria:
-
≥60% mineralization (CO₂ evolved or O₂ consumed) in 28 days.
-
The 10-day window requirement is waived under EU rules.
Group 2 – Enhanced Screening
Methods:
Key Features:
-
Test duration can extend up to 60 days.
-
Larger vessels may be used for better simulation.
Pass Criteria:
-
≥60% mineralization over 60 days.
-
10-day window waived.
Group 3 – Inherent Biodegradability
Method:
Restrictions:
-
Pre-adaptation of inoculum not allowed.
Pass Criteria:
-
≥70% mineralization (O₂ consumed or CO₂ evolved) within 14 days.
Group 4 – Relative Biodegradation vs Reference
Methods (ISO standards):
-
ISO 14852 (CO₂ in aqueous medium)
-
ISO 19679 (seawater/sediment CO₂)
-
ISO 18830 (seawater/sediment O₂)
-
ISO 17556 (soil CO₂ or O₂)
-
ISO 22404 (marine sediment CO₂)
Conditions:
-
No pre-adaptation of inoculum.
-
Reference materials required (e.g., cellulose as positive, polyethylene as negative).
-
Results reported from plateau or maximum degradation achieved.
Pass Criteria:
-
≥90% degradation relative to reference material
-
Within 6 months (aquatic) or 24 months (soil/sediment).
Group 5 – Environmental Simulation Tests
Methods (OECD):
-
OECD 307 (Soil transformation)
-
OECD 308 (Sediment transformation)
-
OECD 309 (Surface water simulation)
Test Conditions:
-
Low temperatures reflecting EU environments:
-
12 °C for freshwater, estuarine water/sediment, and soil
-
9 °C for marine water/sediment
-
Pass Criteria:
-
Half-life <60 days in water
-
Half-life <180 days in sediment or soil
Regulatory Clarifications from OECD EGMP Q&A
To support consistent implementation, the OECD Expert Group on Microplastics (EGMP) has published clarifications that address common questions:
-
Definition of SPM (Synthetic Polymer Microparticles): Solid polymers in particles ≤5 mm, or ≤15 mm with a length-to-diameter ratio >3. Exemptions include natural non-chemically modified polymers, degradable polymers (Appendix 15), soluble polymers (>2 g/L, Appendix 16), and polymers without carbon in their structure.
-
Degradable vs Derogated: Polymers that pass Appendix 15 tests are regarded as degradable. They are excluded from the scope of Entry 78 and are not subject to instructions for use, disposal requirements, or reporting. However, proof of degradability must be provided to competent authorities upon request.
-
Emulsions Not SPM: Since emulsions are liquid-liquid mixtures, polymers in emulsions are not considered SPM (which are defined as solid).
-
QC Testing for Physical State: Determining whether a polymer is solid or liquid can be performed in a company’s quality control laboratory, even without ISO 17025 or GLP accreditation. Only degradability and solubility testing (Appendices 15/16) require accredited labs.
-
Supplier Declarations: A supplier’s “non-microplastic” statement can be used, but companies remain fully responsible for compliance. If degradability or solubility is claimed, supporting data must be available on request.
Testing with Situ Biosciences
For many polymers, Groups 1–3 are the fastest route to exemption, while Groups 4–5 provide stronger environmental realism when needed.
We work with clients to:
-
Select applicable OECD/ISO method for their polymer.
-
Deliver defensible studies that align with EU Appendix 15/16 requirements.
-
Deliver ISO 17025-compliant biodegradability data to support exemptions from the EU microplastics restriction.
📩 For more information about biodegradability testing, contact the biodegradation lab at 847-483-9950 or info@situtest.com.