Antifungal & Mold Resistance Testing
Antifungal and mold resistance testing shows whether a material, coating or finished product resists fungal growth when it is exposed to mold spores in warm, humid conditions. Situ Biosciences runs 14 standard fungal resistance methods, plus custom protocols, in our ISO 17025 accredited lab near Chicago. The methods include ASTM G21, ASTM D3273, AATCC 30, ISO 846 and MIL-STD-810.
Mold growth stains surfaces, weakens materials, causes odors and can trigger product failures or recalls. Testing tells you whether your antifungal additive or treatment works before your product reaches customers.
Which Mold Resistance Test Do You Need?
The right method depends on what your product is made of and where it will be used.
| Material or product | Method | What it measures | Typical duration |
|---|---|---|---|
| Plastics and synthetic polymers | ASTM G21 | Resistance of polymers to fungal growth, rated 0–4 | 28 days |
| Plastics exposed to the environment | ISO 846 | Effect of fungi and bacteria on plastics (Methods A–D) | Per method |
| Interior paints and coatings | ASTM D3273 | Mold growth on coated panels in an environmental chamber, rated 0–10 | 4 weeks |
| Paint films and coatings | ASTM D5590 | Fungal defacement on an accelerated agar plate assay | 4 weeks |
| Textiles and fabrics | AATCC 30 | Mildew and rot resistance of textiles | 2 weeks (up to 6) |
| Textiles, quick screen | AATCC 30 Part 3 | Fungal growth on fabric, 7-day or 14-day version | 7 or 14 days |
| Paper and paperboard | ASTM D2020 | Mildew resistance of paper | 14 days |
| Adhesives | ASTM D4300 | Fungal growth and zone of inhibition on adhesive films | 4 weeks |
| Insulation and facings | ASTM C1338 | Fungal resistance of insulation materials | 28 days |
| Retroreflective sheeting | ASTM D4956 | Fungus resistance after leaching, with Aspergillus niger | 14 days |
| Military equipment | MIL-STD-810 Method 508 | Fungal growth on equipment and materials | 28 days minimum |
| Electronic test equipment | MIL-PRF-28800F | Fungal growth on electronic equipment | 28 days |
| Avionics | RTCA DO-160G | Fungal resistance of airborne equipment | 28 days minimum |
| Electronics (India) | JSS 55555 | “Penta-Five” fungal growth test for electronics | Per standard |
| Printed boards | IPC-TM-650 2.6.1 | Fungus resistance of printed board materials | Per standard |
Not sure which method fits? Tell us your material, end use and the claim or specification you need to meet, and we will recommend one.
How Mold Resistance Testing Works
- Prepare specimens. We test your treated material alongside an untreated control, or a certified reference control.
- Inoculate. Specimens are sprayed or inoculated with a spore suspension of the fungi the method specifies, such as Aspergillus brasiliensis, Penicillium, Chaetomium globosum, Trichoderma or Aureobasidium pullulans.
- Incubate. Specimens go into a warm, humid chamber that favors mold growth, for 1 to 4 weeks or longer depending on the method.
- Rate growth. Our microbiologists rate visible fungal growth at set intervals using the method’s scale.
- Report. You receive ratings for each specimen and the control, compared against the method’s criteria or your specification.
How Results Are Rated
| Method | Rating scale | Best result |
|---|---|---|
| ASTM G21 | 0 (no growth) to 4 (heavy growth, more than 60% coverage) | 0 |
| ASTM D3273 | 0 (complete defacement) to 10 (no growth) | 10 |
| AATCC 30 | Visible growth and, for some tests, loss of fabric strength | No growth, minimal strength loss |
Fungal Resistance vs. Fungicidal Efficacy
Fungal resistance testing measures whether a surface stops mold from growing on it over weeks. Fungicidal efficacy testing measures whether a disinfectant or sanitizer kills fungi on contact in minutes. If you make a disinfectant with fungicidal claims, you need an efficacy method such as EN 1650 or EN 13697, not a resistance test.
Certified Reference Materials for Antifungal Tests
Situ Biosciences is an ISO 17034 accredited reference material producer. Our certified treated and untreated controls for ASTM G21 and AATCC 30 Part 3 give labs and manufacturers a known result to verify method performance. About our accreditations →
Industries We Test For
Paint & Coatings · Plastics · Textiles · Electronics · Military · Paper · Foam · Concrete
Learn More About Mold and Antifungal Testing
- Black mold: Aspergillus niger in antifungal testing
- Antifungal testing using Trichoderma pinophilus for material durability
- Avoid mold and mildew-related consumer product recalls
Ready to test? Call 847-483-9950, email info@situtest.com or request a quote →
Frequently Asked Questions
What is mold resistance testing?
Mold resistance testing exposes a material or product to fungal spores in warm, humid conditions and measures how much mold grows on it over time. Results are compared with an untreated control to show whether an antifungal treatment protects the product.
What is the difference between ASTM G21 and ASTM D3273?
ASTM G21 tests synthetic polymers such as plastics, rubber and sealants on nutrient-salts agar with no carbon source for 28 days and rates growth from 0 to 4. ASTM D3273 tests interior paints and coatings on panels in a humid environmental chamber for 4 weeks and rates growth from 10 (none) down to 0.
How long does fungal resistance testing take?
Most methods run 2 to 4 weeks once specimens are inoculated. ASTM G21, ASTM C1338 and MIL-STD-810 run 28 days, and ASTM D2020 runs 14 days. AATCC 30 Part 3 has a 7-day screening version.
Which fungi are used in antifungal testing?
Each method specifies its own organisms. Common test fungi include Aspergillus brasiliensis (formerly A. niger), Penicillium species, Chaetomium globosum, Trichoderma species and Aureobasidium pullulans.
Can my product claim to be mold resistant after it passes a test?
A passing result supports claims that a treatment protects the product itself. In the U.S., claims that a product protects people or kills germs on other surfaces may require EPA registration. Ask us about antimicrobial compliance before you finalize label language.
Can you run a custom or modified mold resistance test?
Yes. We can adjust organisms, duration, conditioning (such as leaching or weathering) or specimen size to match your product’s real-world use. We’ll document the changes so your results stay defensible.